Model TWBS.EWE, low-lead Emergency Valve (patent pending) thermostatically mixes hot and cold water to provide a safe fluid supply for emergency eyewash equipment. The valve contains a secondary high temperature limit valve to provide additional protection to the user in the event of main tempering valve malfunction. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 12 gpm (3.8 to 45.4 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (83% of rated tepid flow rate)
- Low-lead brass valve design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve binding
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85° F (29° C)
- Tempered water: High temperature limit is factory set to 87°F (30° C)
- Cold water by-pass valves are closed during normal operation, regardless of flow rate
- For important installation information, please read Scald Warning.
Listings: CSA certified per ASSE 1071, ANSI Z358.1, applicable sections of CSA B125.3, NSF/ANSI 372, NSF/ANSI 61-section 8, California Health and Safety Code 116875 (AB 1953).
TWBS.HF – Thermostatic Mixing ValveModel TWBS.HF, low-lead Emergency Valve (patent pending), thermostatically mixes hot and cold water to provide a safe fluid supply for emergency shower and eyewash equipment. The valve contains a secondary high temperature limit valve to provide additional protection to the user in the event of main tempering valve malfunction. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a pressure sensing diverter valve is provided that sends a pressure signal to open the cold water by-pass valve in the event of hot water pressure loss, main valve thermostat malfunction, or clogged cold water check-stop. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 78 gpm (295 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (100% of rated tepid flow rate)
- Low-lead brass valve design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve sticking
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85° F (29° C)
- Tempered water: High temperature limit is factory set to 87° F (30° C)
- Cold water by-pass valves are closed during normal operation, regardless of flow rate
- For important installation information, please read Scald Warning.
Listings: CSA certified per ASSE 1071, ANSI Z358.1, applicable sections of CSA B125.3, NSF/ANSI 372, NSF/ANSI 61-section 8, California Health and Safety Code 116875 (AB 1953).
TWBS.SHE – Thermostatic Mixing ValveModel TWBS.SHE, low-lead Emergency Valve (patent pending), thermostatically mixes hot and cold water to provide a safe fluid supply for emergency shower and eyewash equipment. The valve contains a secondary high temperature limit valve to provide additional protection to the user in the event of main tempering valve malfunction. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 74 gpm (280 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (68% of rated tepid flow rate)
- Low-lead brass valve design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve binding
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85° F (29° C)
- Tempered water: High temperature limit is factory set to 87° F (30° C)
- Cold water by-pass valves are closed during normal operation, regardless of flow rate
- For important installation information, please read Scald Warning.
Listings: CSA certified per ASSE 1071, ANSI Z358.1, applicable sections of CSA B125.3, NSF/ANSI 372, NSF/ANSI 61-section 8, California Health and Safety Code 116875 (AB 1953).
9202E – Thermostatic Mixing ValveModel 9202E Emergency Valve (patent pending) thermostatically mixes hot and cold water to provide a safe fluid supply for emergency showers and eyewash equipment. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate measurement.)
- A flow rate of 1 to 78 gpm (295 L) for better temperature control across the operating range
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (64% of rated tepid flow rate)
- Brass valve design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve sticking
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85° F (29° C)
- Tempered water: High temperature limit is factory set to 90° F (32° C)
- Cold water by-pass valves are closed during normal operation, regardless of flow rate
- For important installation information, please read Scald Warning.
CSA Listings: CSA certified per ASSE 1071, ANSI Z358.1 and applicable sections of CSA B125.3.
9201E – Thermostatic Mixing ValveModel 9201E emergency mixing valve (patent pending) thermostatically mixes hot and cold water to provide a safe fluid supply for emergency showers and eyewash equipment. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 31 gpm (3.8 to 117.3 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (65% of rated tepid flow rate)
- Brass valve design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve sticking
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85° F (29° C).
- Tempered water: High temperature limit is factory set to 90° F (32° C).
- Cold water by-pass valves are closed during normal operation, regardless of flow rate.
- For important installation information, please read Scald Warning.
CSA Listings: CSA certified per ASSE 1071, ANSI Z358.1, and applicable sections of CSA B125.3.
9201EFE – Thermostatic Mixing ValveModel 9201EFE Emergency Thermostatic Mixing Valve (patent pending) thermostatically mixes hot and cold water to provide a safe fluid supply for emergency eyewash equipment. Additionally, to ensure a fail-safe water supply for emergency eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 12 gpm (3.8 to 45.4 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (83% of rated tepid flow rate)
- Brass valve design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates Thermostatic Mixing Valve sticking
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85° F (29° C).
- Tempered water: High temperature limit is factory set to 90° F (32° C).
- Cold water by-pass valves are closed during normal operation, regardless of flow rate.
- For important installation information, please read Scald Warning.
CSA Listings: CSA certified per ASSE 1071, ANSI/ISEA Z358.1 and applicable sections of CSA B125.3.
9201EW – Thermostatic Mixing ValveModel 9201EW Emergency Valve thermostatically mixes hot and cold water to provide a safe fluid supply for a single emergency eye/face wash. Additionally, to ensure a fail-safe water supply for emergency eyewash stations, a cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 10 gpm (3.8 to 37.8 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Cold Water Bypass flow rate of 3.8 gpm (14.4 L) (When tested under conditions specified in ASSE 1071)
- Brass valve design with supplied check valves
- Over-sized valve seats resist failures caused by foreign matter
- Efficient funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85° F (29° C).
- Tempered water: High temperature limit is factory set to 90° F (32° C).
- For important installation information, please read Scald Warning.
CSA Listings: CSA certified per ASSE 1071, ANSI Z358.1 and applicable sections of CSA B125.3.
9201H – Thermostatic Mixing ValveModel 9201H, low-lead Emergency Valve (patent pending), thermostatically mixes hot and cold water to provide a safe fluid supply for emergency showers and eyewash equipment. The valve contains a secondary high temperature limit valve to provide additional protection to the user in the event of main tempering valve malfunction. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet downstream for the most accurate measurement.)
- A flow rate of 1 to 31 gpm (3.8 to 117.3 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (65% of rated tepid flow rate)
- Low-lead brass valve design with internal check stops
- Oversized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve sticking
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85° F (29° C)
- Tempered water: High temperature limit is factory set to 87° F (30° C)
- Cold water by-pass valves are closed during normal operation, regardless of flow rate
Listings: CSA certified per ASSE 1071, ANSI Z358.1, applicable sections of CSA B125.3, NSF/ANSI 372, NSF/ANSI 61-section 8, California Health and Safety Code 116875 (AB 1953).
5881 – Air Control ValveModel 5881 fountain valve is a push-button activated lead-free air valve used on all freeze-resistant drinking fountains. It is diaphragm controlled, supplied with an in-line mesh Y-strainer, and 1/2″ NPT inlet and outlet. Note: Push button assembly and flow control not included.
Haws manufactures drinking fountains, faucets and electric water coolers to be lead-free by all known definitions including NSF/ANSI/CAN 61- Section 9, NSF/ANSI/CAN 372, California Proposition 65, and the Federal Safe Drinking Water Act. Product is compliant to California Health and Safety Code 116875 (AB 1953-2006), and NSF/ANSI/CAN 61: Q ≤ 0.5.
6252EHLF – Faucet ValveModel 6252EHLF bib faucet is designed with a self-closing lever action and requires less then 3.5 pounds (1.6 kg) to activate, easily operable by the handicapped. Combining the lead-free design, with a rough brass finish, this faucet is built to last in outdoor environments. Unit also comes equipped with extended lever handle for ease of use.
- Connection is 1/2″ NPT inlet.
- Haws manufactures drinking fountains, faucets and electric water coolers to be lead-free by all known definitions including NSF/ANSI/CAN 61- Section 9, NSF/ANSI/CAN 372, California Proposition 65, and the Federal Safe Drinking Water Act. Product is compliant to California Health and Safety Code 116875 (AB 1953-2006), and NSF/ANSI/CAN 61: Q ≤ 1.