Model HWUACP8L, barrier-free "Hi-Lo", wall mounted self-contained 8 gph electric water cooler with granite powder-coated paint on galvanized steel.
This model has been discontinued.
Model HWUACP8L bi-level barrier-free pressure drinking water cooler shall deliver a minimum of 8 gph (30.3 LPH) of water at 50°F (10°C) cooled from 80°F (26.7°C) inlet water at 90°F (32.2°C) ambient. Each cooler shall have front and side mounted push pads requiring less than 5 pounds of force to activate that initiate water flow through a flexible hooded rubber bubbler having a non-squirt feature. An internally mounted valve and adjustable stream regulator shall control water flow between 20 and 90 psig. R-134a refrigeration system shall be hermetically sealed and refrigerant flow shall be capillary tube controlled. An adjustable thermostat having an off position shall control refrigeration system. Stainless steel top shall have integral drain strainer. Heavy-duty galvanized frame shall support powder-coated galvanized exterior panels. Potable water system components shall comply with the Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be Certified to ANSI/NSF Standard 61, Section 9. Chilled water capacity shall be rated per ARI Standard 1010. Cooler shall be Listed by Underwriters Laboratories Inc. to U.S. and Canadian safety standards. Drinking water cooler shall comply with ANSI A117.1 and ADA frontal approach and protruding object requirements.The vast majority of Haws products qualify under the terms of the act. However, since different purchases often require subtly different responses, Haws recommends that the specific document requesting certification be sent to customer service for a specific answer.
Glass Filler |
|
Filter |
U.S. List Price: Contact Us for Pricing Pricing Terms
Clean and polish with Wright's silver cream; or use mild detergent, liquid soap, or commercial chrome polish. Do not use abrasive or caustic cleaners.
Model HWUACP8L "Hi-Lo" pressure drinking water cooler shall deliver a minimum of 8 gph (30.3 LPH) of water at 50°F (10°C) cooled from 80°F (26.7°C) inlet water at 90°F (32.2°C) ambient. Each fountain shall have front and side mounted push-pads requiring less than 5 pounds of force to activate that initiate water flow through a flexible hooded rubber bubbler having a non-squirt feature, internally mounted valve and adjustable stream regulator shall control water flow between 20 and 90 psig. R-134a refrigeration system shall be hermetically sealed and refrigerant flow shall be capillary tube controlled. Adjustable thermostat having an off position shall control refrigeration system. Stainless steel top with integral drain strainer. Heavy-duty galvanized frame shall support Granite powder-coated galvanized exterior panels. Built-in 100 micron strainer and external stream height adjustment. 115 Volts, 60Hz, Full Load Amps: 4.6, and Rated Watts: 460
No Reviews Yet